in combination with a safe elevator control system or evaluation unit (SAFEBOX), safety functions up to SIL3 can be fullfilled
| Measuring principle: | absolute | 
| Measurement: | linear | 
| Maximum measuring length | 262 m | 
| Speed: | max. 10 m/s (higher speeds on request) | 
| Resolution: | 0.0625 mm | 
| Repeat accuracy: | ±1 Increment | 
| System accuracy in µm at 20°C: | ±(1000 + 100 x L) L = measuring length in meter | 
| Distance from sensor to magnetic tape | 4 mm | 
| Dimensions (without cable): | L x W x H = 355 x 85 x 48 mm | 
| Housing material: | aluminium | 
| Connection: | 5-pin M12 round connector | 
| Sensor cable: | 2 m, 3.2 m and 5 m standard cable length (others upon request) | 
| Weight: | approx. 900 g without cable (cable approx. 60 g/m) | 
| Required magnetic tape: | AB20-80-10-1-R-D-15-BK80 | 
| Supply voltage: | + 18 … 29 VDC (stabilized) in dual-channel operation + 10 … 18 VDC (stabilized) in single-channel operation You must use a power supply with Safety Extra Low Voltage (SELV) or Protective Extra Low Voltage (PELV). | 
| Residual ripple: | < 100 mVpp | 
| Reverse voltage protection: | integrated | 
| Power input: | max. 200 mA @ 24 VDC without loading the output for the door zone indication | 
| Interfaces: | RS-485 | 
| Protection of the outputs/ interfaces: | RS-485 output: short-circuit-proof output door zone indication: short-circuit-proof to GND, but not to +24 V | 
| Cable length: | according to EIA RS-485 specifications | 
| Maximum operating time: | 20 years, reduced depending on ambient conditions | 
| Storage temperature: | -20 °C … +85 °C | 
| Operation temperature: | -20 °C … +70 °C standard version -20 °C … +75 °C extended requirements Note that these specifications for both versions only apply up to an operating altitude of 2000 m above sea level. Above this limit, the maximum ambient temperature is lower due to the lower cooling capacity of the ambient air. | 
| Humidity: | max. 95 %, non-condensing | 
| Protection class: | IP54 (according to EN 60529) | 
| Operation height: | max. 3000 m absolute altitude standard version max. 4000 m absolute altitude extended requirements | 
| EMC transient emission/immunity: | according to EN 12015 / EN 12016 | 
| Vibration/shock resistance: | according to EN 60068-2-6 / EN 60068-2-27, EN 60068-2-29 |