*recommended
Measuring principle | pseudo-absolute |
Repeat accuracy | ± 1 increment |
System accuracy in µm at 20 °C | ±(1000 + 50 x L) L = measuring length in meters |
Distance sensor / tape | the correct distance is guaranteed by guidance |
Housing material | plastic |
Housing dimensions | L x W x H = 82 x 68 x 30 mm |
Required magnetic tape | AB20-80-10-1-R-D-15-BK80 |
Basic pole pitch (magnetic tape) | 8 mm |
Maximum measuring length | 90 m |
Connections | standard RJ45 socket or Mini USB socket |
Sensor cable | external network cable resp. USB cable required |
Weight | approx. 60 g without cable |
Power supply voltage | 10 … 30 VDC resp. 5 VDC with USB interface |
Residual ripple | < 200 mVpp |
Current consumption | max. 150 mA |
Interface | standard: CANopen (CiA 406 or CiA 417) or USB with standard protocol on request: SSI, RS485 |
Resolution | 1.0 / 0.5 / 0.25 / 0.125 / 0.0625 mm |
Operating speed | max. 4 m/s (higher on request) |
Cycle time | 250 µs |
Storage temperature | −25 … +85 C |
Operating temperature | −10 … +70° C (−25 … +85° C on request) |
Operating altitude | max. 3000 m above sea level |
Humidity | max. 95 %, non-condensing |
Protection class | IP43 |