Measuring principle | Absolute |
Repeat accuracy | ±1 increment |
System accuracy in µm at 20°C | ±(1000 + 100 x L) L = measuring length in meters |
Distance sensor / magnetic tape | the correct distance is guaranteed by guidance |
Basic pole pitch | 8 mm |
Sensor housing material | aluminium |
Sensor housing dimensions | L x W x H = 354 x 135 x 54 mm |
Necessary magnetic tape | AB20-80-10-1-R-D-15-BK80 |
Maximum measuring length | 262 m |
Connections | 2 outlets with open wire ends for PIO and SCA cables (plug connectors on request) M12 4 pole male for eSGC; according to ICE61067-2-101 |
Sensor cable (PIO, SCA) | standard length: 3.0 m (others on request) |
Weight | approx. 1400 g without cable; cable: approx. 60 g per meter |
Supply voltage | 18[1] ... 30[2] VDC (stabilized). A SELV/PELV power supply must be used | |
Residual ripple | < 100 mV | |
DZO rating | + 24 VDC −20 %, max.200 mA (PNP) | |
Reverse polarity protection | integrated | |
Power input | max. 600 mA at 24 VDC | |
Interfaces | CAN: CANopen DS406 or DS417 | |
Digital input voltage | 18 … 30 VDC for high level; open for low level | |
Relay contact rating OC, SR1, SR2 | · 0...230VAC (max. 250VAC), max. 2A · 24VDC (max. 30VDC), max. 1A · 48VDC (max. 53VDC), max. 600mA · 110VDC (max. 120VDC), max. 250mA each with a resistive/inductive load with L/R < 40 ms | |
Rating for external supply of SGC-actuator | 24 VDC, min. 18 V; max. 30 V; constraints for connected trip coil to be observed |
Storage temperature | −25 … +85° C |
Operation temperature | −20 … +65° C |
Humidity | max. 95 %, non-condensing |
Protection class | IP54 (according to EN60529), higher on request |
Interference emission / immunity | EN 12015 / EN 12016 |
Vibration / shock resistance | EN 60068-2-6 / EN 60068-2-27, EN 60068-2-29 |
Others | |
Maximum operating time | 20 years |
Safety relay contact reaction time | < 55 ms |
Solid state contact (eSGC) reaction time | < 45 ms |